Detail Autotrol 255
Autotrol 255 Control Valves Quick Response + 6281385066789 Email : sales@ profilterindonesia.com
Built with the business professional in mind - fast installation and quicker service calls increase profit
3/ 4– inch port opening provides good softener flow performance
Includes a clear-sight air check for easy brine line troubleshooting
Efficient valve design decreases the amount of water required for regeneration
Tank adapter permits disconnection from valve without disturbing the resin bed
Pentair Water offers a full range of Autotrol Control Valves to meet all residential water conditioning applications.
Autotrol 255 Control Valves
Specifications
Electrical
Controller Operating Voltage 12 Volt – AC ( Requires use of Pentair Water® -supplied transformer)
Input Supply Frequency 50 or 60 Hz ( Controller configuration dependent)
Motor Input Voltage 12 Volt – AC
Controller System Power Consumption 3 Watts average
Design Specifications/ Ratings
Valve Body Glass-filled thermoplastic – NSF Listed material
Rubber Components Compounded for cold water – NSF Listed material
Valve Materials Certification WQA Gold Seal Certified to ORD 0902 and
NSF/ ANSI 44 Rated component for material safety
Weight ( Valve with Control) 4 Ibs ( 1.8 kg)
Recommended Operating Pressure 20 - 120 psi ( 1.38 - 8.27 bar)
Canada 20 - 100 psi ( 1.38 - 6.89 bar)
Hydrostatic Test Pressure 300 psi ( 20.69 bar)
Water Temperature 35° - 100° F ( 2° - 38° C)
Ambient Temperature* 35° - 120° F ( 2° - 48.9° C)
Valve Connections
Tank Thread 2-1/ 2-inches – 8, male
Inlet/ Outlet Manifold 1-inch NPT or BSPT, female
Drain Line 1/ 2-inch ( manifold dependent)
Brine Line 1/ 4-inch or 3/ 8-inch NPT, male air check built into valve
Flow Rates ( Valve Only)
Service @ 15 psi ( 1.03 bar) drop 15.5 gpm ( 3.52 m3/ h)
Backwash @ 25 psi ( 1.72 bar) drop 6.0 gpm ( 1.36 m3/ h)
Logix™ Series
740 Time Clock
Simple, economic electronic time clock ( chronometric)
7- or 99-day regeneration setting
High efficiency regeneration sequence
12-volt operation
Filter or conditioner setting in one control
Operates 255, 263, 268 with one controller
760 Demand
Simple, economic electronic demand ( volumetric)
Calendar override
12-volt operation
28-day variable reserve
High efficiency regeneration sequence
Automatic capacity calculations
Operates 255, 263, 268 with one controller
Autotrol 255 Control Valves